Horstmann HCT2 Arkusz Danych

Przeglądaj online lub pobierz Arkusz Danych dla Grzejniki Horstmann HCT2. Horstmann HCT2 Data Sheet Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 2
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
This cylinder thermostat is fitted to the hot water cylinder to
ensure that water temperature is controlled to a safe
temperature whilst also saving energy by stopping
uncontrolled heating of the hot water.
This type of cylinder stat is intended for use as part of a fully
pumped heating and hot water system
in conjunction with motorised zone valves a room
thermostat and a two channel central heating programmer.
Ÿ 230V mains operation
Ÿ Adjustable temperature range 20°C to 90°C
Ÿ 16 Amp changeover (S.P.D.T.) contacts
Ÿ Switching differential of approximately 8°C
Ÿ Bimetallic sensor system
HCT2
Hot Water Cylinder Thermostat
Przeglądanie stron 0
1 2

Podsumowanie treści

Strona 1 - Ÿ Bimetallic sensor system

This cylinder thermostat is fitted to the hot water cylinder to ensure that water temperature is controlled to a safe temperature whilst also saving e

Strona 2 - Specification

Cylinder Thermostat – HCT2With an adjustable temperature range of between 20°C to 90°C, the Horstmann cylinder thermostat is suitable for mounting on

Komentarze do niniejszej Instrukcji

Brak uwag