C-Stat 11-ZW | C-Stat 17-ZWInstallation InstructionsWireless Programmable Room Thermostat and ASR-ZW Receiver1Programmable room thermostats are widely
Pairing the C-Stat ZW programmable room thermostat with ASR-ZW receiverThe C-Stat uses the latest Z-Wave wireless communication technology to g
Procedure A1. On the C-Stat programmable stat, Press ENTER twice2. Press '-' or '+' to select SETUP3. Press ENTER4. Press '-&
Procedure B1. On the C-Stat programmable stat, Press ENTER twice2. Press '-' or '+' to select SETUP3. Press ENTER4. Press '-&
Installer SettingsThere are a number of 'Installer Settings' that should be set on installation.These can be found under the 'SET UP ME
Resetting the C-StatElectronic equipment can in some circumstances be affected by electrical interference.If the display becomes frozen or scrambled s
Specification – C-Stat 11-ZW | C-Stat 17-ZWThermostatPower Supply 2 x AA BatteriesContact type Micro-disconnectionWiring configuration Voltage f
Secure Controls (UK) LimitedSouth Bristol Business Park, Roman Farm Road, Bristol BS4 1UPE-mail: [email protected] site: www.horstmann.co.ukPar
2Installing the ASR-ZW receiverThe ASR-ZW receiver should be located as near as is practical to the boiler or zone valve to be controlled, as well as
3Electrical ConnectionsWARNING: ISOLATE THE MAINS SUPPLY BEFORE COMMENCING INSTALLATIONAs the C-Stat is a wireless product with no electrical con
Example circuit diagrams for typical boiler installations are shown below. These diagrams are schematic and should be used for guidance
5N LONOFFONOFFHOTWATERCENTRALHEATINGPUMP&BOILERProgrammerASR ReceiverMAINSSUPPLYMAINSSUPPLYNLENLENLROOMSTATSATCALLSATCALLCYLSTATC CN1 2 3 4C-Stat
C-Stat ASR Receiver replacing a conventional room thermostat on a fully pumped system with existing programmer and two spring return valves with auxi
TPI Temperature control softwareThermostats using TPI (Time Proportional Integral) control algorithms will reduce the temperature swing th
Fitting the C-Stat Programmable Room ThermostatBefore final installation it is advisable to commission the product and ensure that the Thermostat
Before fixing the wall plate in position check to see that the thermostat and receiver are still able to communicate satisfactorily