Procedure B
1. On the C-Stat programmable stat, Press ENTER twice
2. Press '-' or '+' to select SETUP
3. Press ENTER
4. Press '-' or '+' to select SET UP Z-WAVE
5. Press ENTER
6. Press '-' or '+' to select NETWORK RESET
7. Press ENTER
8. Press ENTER again to confirm and NETWORK RESET
COMPLETE will appear on the display
9. Press BACK to go back to SET UP Z-WAVE
10. Press ENTER
11. Press '-' or '+' to select EXCLUDE NODE / RECEIVER
12. Press ENTER
13. Go to the Powered ASR-ZW receiver, press and hold the
network button
14. EXCLUDING will appear on the display of the C-Stat
15. When completed NODE / EXCLUDED will appear on the
display.
16. The red network light on the ASR-ZW will start flashing
17. Once the red light is flashing follow Procedure A on page
11